==Key Documents== | ==Key Documents== | ||
+ | |||
+ | *[https://indico.fnal.gov/internalPage.py?pageId=0&confId=12749 Cold Electronics review webpage] | ||
+ | * [http://docs.dunescience.org:8080/cgi-bin/ShowDocument?docid=1484 Front End ASIC datasheet] | ||
+ | * [http://docs.dunescience.org:8080/cgi-bin/ShowDocument?docid=1485 Cold ADC ASIC datasheet] | ||
+ | * [http://docs.dunescience.org:8080/cgi-bin/ShowDocument?docid=415 ColDATA specification] | ||
+ | * [http://docs.dunescience.org:8080/cgi-bin/ShowDocument?docid=1755 Cold Cable datasheets] | ||
+ | * [http://docs.dunescience.org:8080/cgi-bin/ShowDocument?docid=1745 Warm Interface documentation] | ||
+ | |||
+ | ===Publications=== | ||
+ | ''LAr TPC Electronics CMOS Lifetime at 300 K and 77 K and Reliability Under Thermal Cycling'', Shaorui Li (BNL, NSLS) , Jie Ma (SUNY, Stony Brook) , Gianluigi De Geronimo, Hucheng Chen, Veljko Radeka (BNL, NSLS), | ||
+ | [http://dx.doi.org/10.1109/TNS.2013.2287156 IEEE Trans.Nucl.Sci. 60 (2013) 4737-4743] | ||
+ | |||
+ | ''Front End Readout Electronics of the MicroBooNE Experiment'', H. Chen, G. De Geronimo, F. Lanni, D. Lissauer, D. Makowiecki, V. Radeka, S. Rescia, C. Thorn, B. Yu (Brookhaven), [http://dx.doi.org/10.1016/j.phpro.2012.02.471 Phys.Procedia 37 (2012) 1287-1294] | ||
+ | |||
+ | ''Readout electronics for the MicroBooNE LAr TPC, with CMOS front end at 89K'', H. Chen, K. Chen, G. De Geronimo, F. Lanni, D. Lissauer, D. Makowiecki, V. Radeka, S. Rescia, C. Thorn, B. Yu (Brookhaven), [http://dx.doi.org/10.1088/1748-0221/7/12/C12004 JINST 7 (2012) C12004] | ||
+ | |||
+ | ''Front-end ASIC for a Liquid Argon TPC'', Gianluigi De Geronimo (Brookhaven) et al.., [http://dx.doi.org/10.1109/TNS.2011.2127487 IEEE Trans.Nucl.Sci. 58 (2011) 1376-1385] | ||
+ | |||
+ | ==APA electronics interface== | ||
+ | |||
+ | [http://docs.dunescience.org:8080/cgi-bin/ShowDocument?docid=1482 RC-Board layouts] | ||
Line 18: | Line 39: | ||
==Cold Cables== | ==Cold Cables== | ||
− | ==Warm Electronics Crate (WEC) == | + | [[Image:ColdDataCable.png|300px|Caption First Cold Signal cable from Samtec]] |
+ | |||
+ | [http://docs.dunescience.org:8080/cgi-bin/RetrieveFile?docid=1755&filename=HDR-192192-XX.PDF Cold Data Cable drawing ] | ||
+ | |||
+ | [[Image:DataCable-signal-map.png|300px|Caption Cold Data Cable Signal Map]] | ||
+ | |||
+ | [http://docs.dunescience.org:8080/cgi-bin/RetrieveFile?docid=1755&filename=THV_500G.pdf Technical description of the cold data cable insulation ] | ||
+ | |||
+ | [http://docs.dunescience.org:8080/cgi-bin/RetrieveFile?docid=1755&filename=3M-Fluroplastic-data-sheet.pdf Material Data Safety sheet for THV_500G] | ||
+ | |||
+ | [http://docs.dunescience.org:8080/cgi-bin/RetrieveFile?docid=1755&filename=ASD-193456-01.pdf Cold Power Cable drawing ] | ||
+ | |||
+ | ==Warm Electronics == | ||
+ | |||
+ | ===Warm Electronics Crate (WEC)=== | ||
+ | |||
+ | ===Power Timing Card (PTC)=== | ||
+ | [http://docs.dunescience.org:8080/cgi-bin/ShowDocument?docid=1745 SBND WIB/PTC documentation] | ||
+ | |||
+ | ===Warm Interface Boards (WIB)=== | ||
==Racks Power and warm cables== | ==Racks Power and warm cables== | ||
+ | |||
+ | The 12V power to the Warm Interface Carte is provided by Weiner MPOD power supplies. ProtoDUNE will use MODEL Mpod LX-R mainframes. Which are the Mpod crates with fan and controller; 8U;10slots; rear modules; with display local control;up to 3kW LV/600W HV. The LV power module to the WEC is the <POD LV module MPV8016I, The MPV8016I is an 8 channel, 0 to 15V with 5A per channel rating; 50W/ch power capacity ; 125V floating isolation; and <2mVp-p ripple. | ||
+ | |||
+ | [[Image:WeinerMPOD_crate.jpg|300px|Caption Weiner MPOD HV/LV Crate]] | ||
+ | |||
+ | [http://www.wiener-d.com/sc/power-supplies/mpod--lvhv/mpod-crate.html Wiener MPOD web page] | ||
+ | |||
+ | [http://www.wiener-d.com/sc/power-supplies/mpod--lvhv/mpod-lv-module.html Weiner MPOD LV module web page] | ||
+ | |||
+ | [http://docs.dunescience.org:8080/cgi-bin/RetrieveFile?docid=1775&filename=WIENER_MPOD_Manual_2.9.pdf MPOD Manual ] | ||
+ | |||
+ | [http://docs.dunescience.org:8080/cgi-bin/RetrieveFile?docid=1775&filename=MPOD%20Crate%20%7C%20MPOD%20-%20LV%3AHV.pdf LV Module Technial Spec ] | ||
+ | |||
+ | [http://docs.dunescience.org:8080/cgi-bin/RetrieveFile?docid=1775&filename=MPOD%20Crate%20%7C%20MPOD%20-%20LV%3AHV.pdf MPOD Crate Tech Spec ] | ||
+ | |||
+ | [http://www.wiener-d.com/sc/power-supplies/mpod--lvhv/mpod-hv-module.html MPOD HV module web page ] | ||
+ | |||
+ | As an alternate power distribution the Wiener PL500 series LV power modules are considered. | ||
+ | |||
+ | [[Image:tnail-1PL506512.jpg|300px|Caption Weiner PL5006 LV Supply]] | ||
+ | |||
+ | [http://www.wiener-d.com/sc/power-supplies/pl500/pl506.html Weiner PL500 power system] | ||
==Slow Control== | ==Slow Control== | ||
− | |||
= Test Stands = | = Test Stands = | ||
Line 31: | Line 92: | ||
==ADC test== | ==ADC test== | ||
− | + | ==FEMB test == | |
+ | |||
+ | == Cable Tests == | ||
− | == | + | ==BNL Integration test== |
− | = | + | =ProtoDUNE Electronics installation= |
=Interface Control Documents= | =Interface Control Documents= | ||
* [http://docs.dunescience.org:8080/cgi-bin/ShowDocument?docid=200 CF Far Site Caverns <--> Far Detector Construction] | * [http://docs.dunescience.org:8080/cgi-bin/ShowDocument?docid=200 CF Far Site Caverns <--> Far Detector Construction] | ||
+ | |||
+ | =Grounding and Shielding= | ||
+ | [https://indico.fnal.gov/getFile.py/access?contribId=5&resId=0&materialId=slides&confId=11995 Grounding Overview talk by Terri] | ||
+ | |||
+ | [http://docs.dunescience.org:8080/cgi-bin/ShowDocument?docid=879 Summary documents on grounding] | ||
+ | |||
+ | =Management= | ||
+ | [http://lbne2-docdb.fnal.gov:8080/cgi-bin/ShowDocument?docid=10621 Basis of Estimate for Electronics Construction 10kt module] Last revised July 2015. | ||
+ | [http://lbne2-docdb.fnal.gov:8080/cgi-bin/RetrieveFile?docid=10621&filename=BOE%20130.05.08%20DUNE%20CE.xlsx&version=11 BOE worksheet in excel] | ||
=Navigation= | =Navigation= | ||
+ | *[https://www.mediawiki.org/wiki/Help:Formatting formatting help] | ||
*[https://dune.bnl.gov/wiki/Main_Page BNL DUNE wiki home] | *[https://dune.bnl.gov/wiki/Main_Page BNL DUNE wiki home] |
Latest revision as of 14:38, 3 November 2016
Contents
- 1 Cold Electronics
- 2 Test Stands
- 3 ProtoDUNE Electronics installation
- 4 Interface Control Documents
- 5 Grounding and Shielding
- 6 Management
- 7 Navigation
Cold Electronics
Cold Electronics Overview
Picture of the cold electronics and general description
Key Documents
- Cold Electronics review webpage
- Front End ASIC datasheet
- Cold ADC ASIC datasheet
- ColDATA specification
- Cold Cable datasheets
- Warm Interface documentation
Publications
LAr TPC Electronics CMOS Lifetime at 300 K and 77 K and Reliability Under Thermal Cycling, Shaorui Li (BNL, NSLS) , Jie Ma (SUNY, Stony Brook) , Gianluigi De Geronimo, Hucheng Chen, Veljko Radeka (BNL, NSLS), IEEE Trans.Nucl.Sci. 60 (2013) 4737-4743
Front End Readout Electronics of the MicroBooNE Experiment, H. Chen, G. De Geronimo, F. Lanni, D. Lissauer, D. Makowiecki, V. Radeka, S. Rescia, C. Thorn, B. Yu (Brookhaven), Phys.Procedia 37 (2012) 1287-1294
Readout electronics for the MicroBooNE LAr TPC, with CMOS front end at 89K, H. Chen, K. Chen, G. De Geronimo, F. Lanni, D. Lissauer, D. Makowiecki, V. Radeka, S. Rescia, C. Thorn, B. Yu (Brookhaven), JINST 7 (2012) C12004
Front-end ASIC for a Liquid Argon TPC, Gianluigi De Geronimo (Brookhaven) et al.., IEEE Trans.Nucl.Sci. 58 (2011) 1376-1385
APA electronics interface
Cold ASICS
Cold Frond End ASIC
Cold ADC
Front End Motherboards (FEMB)
Cold Cables
Technical description of the cold data cable insulation
Material Data Safety sheet for THV_500G
Warm Electronics
Warm Electronics Crate (WEC)
Power Timing Card (PTC)
Warm Interface Boards (WIB)
Racks Power and warm cables
The 12V power to the Warm Interface Carte is provided by Weiner MPOD power supplies. ProtoDUNE will use MODEL Mpod LX-R mainframes. Which are the Mpod crates with fan and controller; 8U;10slots; rear modules; with display local control;up to 3kW LV/600W HV. The LV power module to the WEC is the <POD LV module MPV8016I, The MPV8016I is an 8 channel, 0 to 15V with 5A per channel rating; 50W/ch power capacity ; 125V floating isolation; and <2mVp-p ripple.
Weiner MPOD LV module web page
As an alternate power distribution the Wiener PL500 series LV power modules are considered.
Slow Control
Test Stands
FE ASIC test
ADC test
FEMB test
Cable Tests
BNL Integration test
ProtoDUNE Electronics installation
Interface Control Documents
Grounding and Shielding
Grounding Overview talk by Terri
Summary documents on grounding
Management