Difference between revisions of "SP - Cold Electronics"

From DUNE
Jump to navigation Jump to search
Line 7: Line 7:
 
==Key Documents==
 
==Key Documents==
  
* [http://docs.dunescience.org:8080/cgi-bin/ShowDocument?docid=200 CF Far Site Caverns <--> Far Detector Construction]
+
* [http://docs.dunescience.org:8080/cgi-bin/ShowDocument?docid=1484 Front End ASIC datasheet]
  
 
==Cold ASICS==
 
==Cold ASICS==

Revision as of 15:20, 24 October 2016

Cold Electronics

Cold Electronics Overview

Picture of the cold electronics and general description

Key Documents

Cold ASICS

Cold Frond End ASIC

Cold ADC

Front End Motherboards (FEMB)

Cold Cables

Caption First Cold Signal cable from Samtec

Cold Data Cable drawing

Caption Cold Data Cable Signal Map

Technical description of the cold data cable insulation

Material Data Safety sheet for THV_500G

Cold Power Cable drawing

Warm Electronics Crate (WEC)

Racks Power and warm cables

The 12V power to the Warm Interface Carte is provided by Weiner MPOD power supplies. ProtoDUNE will use MODEL Mpod LX-R mainframes. Which are the Mpod crates with fan and controller; 8U;10slots; rear modules; with display local control;up to 3kW LV/600W HV. The LV power module to the WEC is the <POD LV module MPV8016I, The MPV8016I is an 8 channel, 0 to 15V with 5A per channel rating; 50W/ch power capacity ; 125V floating isolation; and <2mVp-p ripple.

Caption Weiner MPOD HV/LV Crate

Wiener MPOD web page

Weiner MPOD LV module web page

MPOD Manual

LV Module Technial Spec

MPOD Crate Tech Spec

Slow Control

Test Stands

FE ASIC test

ADC test

FEMB test

Cable Tests

BNL Integration test

ProtoDUNE Electronics installation

Interface Control Documents

Navigation