Difference between revisions of "SP - Cold Electronics"
Jump to navigation
Jump to search
JimStewart (talk | contribs) |
JimStewart (talk | contribs) |
||
Line 40: | Line 40: | ||
===Power Timing Card (PTC)=== | ===Power Timing Card (PTC)=== | ||
+ | [http://docs.dunescience.org:8080/cgi-bin/ShowDocument?docid=1745 SBND WIB/PTC documentation] | ||
===Warm Interface Boards (WIB)=== | ===Warm Interface Boards (WIB)=== |
Revision as of 08:14, 3 November 2016
Contents
Cold Electronics
Cold Electronics Overview
Picture of the cold electronics and general description
Key Documents
- Front End ASIC datasheet
- Cold ADC ASIC datasheet
- ColDATA specification
- Cold Cable datasheets
- Warm Interface documentation
Cold ASICS
Cold Frond End ASIC
Cold ADC
Front End Motherboards (FEMB)
Cold Cables
Technical description of the cold data cable insulation
Material Data Safety sheet for THV_500G
Warm Electronics
Warm Electronics Crate (WEC)
Power Timing Card (PTC)
Warm Interface Boards (WIB)
Racks Power and warm cables
The 12V power to the Warm Interface Carte is provided by Weiner MPOD power supplies. ProtoDUNE will use MODEL Mpod LX-R mainframes. Which are the Mpod crates with fan and controller; 8U;10slots; rear modules; with display local control;up to 3kW LV/600W HV. The LV power module to the WEC is the <POD LV module MPV8016I, The MPV8016I is an 8 channel, 0 to 15V with 5A per channel rating; 50W/ch power capacity ; 125V floating isolation; and <2mVp-p ripple.
Weiner MPOD LV module web page